Connector Pack compatibility
Installing or upgrading to Connector Pack 4.6.1 will ensure that the Visual C++ Runtime 2015 redistributables for both x64 and x86 are either installed or upgraded.
Bravura Security Fabric 10.1.x or 11.x is compatible with Connector Pack 4.0.0 or higher and will make use of the backwards compatibility mode.
Python 3.11.2+ is optional for Connector Pack 4.5.x+ installations but is required for the agtpython
and pxpython
connectors. For older versions of Bravura Security Fabric , there are also alternate versions of the agtpython
and pxpython
connectors located in the agent\alt and interface\alt directories that are compatible for specific Python versions.
Note
Alternate pxpython
connectors were added in Connector Pack 4.5.0.
Instance version | 3.0.x | 3.1.x | 3.2.x | 3.3.0 | 3.3.1 | 3.3.2 | 4.0.x | 4.1.x | 4.2.x | 4.3.x | 4.4.x | 4.5.x | 4.6.x | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
10.1.x | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | |
11.0.x | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | |
11.1.x | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | |
12.0.x | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | |
12.1.x | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | |
12.2.x | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y | |
12.3.x | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | |
12.4.x | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | |
12.5.x | N | N | N | N | N | N | N | N | N | N | Y | Y | Y | |
12.6.x | N | N | N | N | N | N | N | N | N | N | N | Y | Y | |
12.7.x | N | N | N | N | N | N | N | N | N | N | N | N | Y |
The format in which the Connector Pack gathers information by each connector during auto discovery has been modified as of Connector Pack 3.2.0 and Bravura Security Fabric 10.1.0 to support a new listing format when listing users, accounts, groups, group memberships, servers, and subscribers.
See "Auto Discovery" in the Bravura Security Fabric documentation for the formats used for the list files generated during auto discovery.
The backwards compatibility mode uses the previous listing format for the information that is gathered by each connector during auto discovery is used for this case.
When planning an upgrade to Bravura Security Fabric 12.7.1, it is recommended to do one of the following:
Upgrade the Connector Pack to 4.6.1 prior to upgrading Bravura Security Fabric .
Uninstall the Connector Pack and then install Connector Pack 4.6.1.
Connector Pack may also be upgraded or installed after upgrading to Bravura Security Fabric 12.7.1, however the Visual C++ Runtime 2015 (x86) redistributable should be installed prior to doing so.