Messages
PSYNC001I
PSYNC001I – Mainframe Connector SUBSYSTEM INTERFACE ENABLED
Explanation | The Mainframe Connector initialization process has completed. The Mainframe Connector subsystem is up and fully functional. |
System Action | Mainframe Connector processing begins. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC020I
PSYNC020I – Mainframe Connector 7.0.3 INTERFACE ENABLED
Explanation | The MODIFY command interface to Mainframe Connector was enabled as part of Mainframe Connector initialization. Mainframe Connector is now capable of accepting MODIFY and STOP command requests. |
System Action | Mainframe Connector continues initialization. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC031I
PSYNC031I – Mainframe Connector STOP REQUEST ACCEPTED
Explanation | A STOP MFC command was issued and Mainframe Connector has recognized the request. |
System Action | Mainframe Connector termination begins. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC032I
PSYNC032I – Mainframe Connector SUBSYSTEM DISABLED
Explanation | An active Mainframe Connector subsystem has been disabled as the result of a STOP MFC command. |
System Action | Mainframe Connector continues with termination. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC033I
PSYNC033I – Mainframe Connector COMMAND PROCESSING TASK TERMINATION INITIATED
Explanation | Termination of Mainframe Connector has been requested through a STOP MFC command. The Mainframe Connector command processing subtask is being terminated as a result of the STOP command. |
System Action | Mainframe Connector continues with termination. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC034I
PSYNC034I – Mainframe Connector COMMAND PROCESSING TASK TERMINATION COMPLETE
Explanation | Termination of Mainframe Connector has been requested through a STOP MFC command. The Mainframe Connector command processing subtask has been successfully terminated. |
System Action | Mainframe Connector continues with termination. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC041I
PSYNC041I – Mainframe Connector TERMINATED
Explanation | A STOP MFC command was issued and Mainframe Connector has shutdown successfully. |
System Action | Mainframe Connector has ended. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC042I
PSYNC042I – Mainframe Connector TERMINATION WAITING ON FUNCTION ROUTINE PROCESSING
Explanation | A Mainframe Connector subsystem function routine is currently active while Mainframe Connector is attempting to terminate. |
System Action | Mainframe Connector will wait for up to two minutes for the active function routine to complete. If the active function routine has not completed in this wait period, Mainframe Connector will continue with termination. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC043I
PSYNC043I – Mainframe Connector TERMINATING WHILE WAITING FOR FUNCTION ROUTINE PROCESSING
Explanation | A Mainframe Connector subsystem function routine is currently active while Mainframe Connector is attempting to terminate. |
System Action | Message PSYNC042I has been previously issued indicating an active Mainframe Connector function routine. The active function routine has not completed in two minutes and Mainframe Connector will continue with termination processing. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC101I
PSYNC101I – Mainframe Connector LISTENER SERVER TASKS SUCCESSFULLY ATTACHED.
Explanation | The Mainframe Connector listener server has been successfully created. |
System Action | None. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC102I
PSYNC102I – Mainframe Connector LISTENER SERVER TASKS SUCCESSFULLY RESTARTED.
Explanation | An abend has occurred in one of the server subtasks. An internal restart of the server subtask environment was successful. |
System Action | None. |
Operator Response | If the message persists, contact the system programmer. |
System Programmer Response | If the cause of the subtask abend cannot be determined and the condition persists, contact Bravura Security for technical support. |
PSYNC111I
PSYNC111I – Mainframe Connector bind() INDICATES EADDRINUSE. ATTEMPT TO BIND WILL CONTINUE FOR ONE MINUTE.
Explanation | The Mainframe Connector listener failed to bind to the socket specified on the LISTENPORT# start parameter. |
System Action | The bind failure code indicates that the port is currently in use and Mainframe Connector will try to bind every two seconds for a period of one minute. |
Operator Response | If the message persists, contact the system programmer. |
System Programmer Response | If the Mainframe Connector listener fails to bind to the specified port, determine if the port is in use by another application or if it has been reserved for use elsewhere. |
PSYNC112I
PSYNC112I – Mainframe Connector LISTENER IS ACTIVE.
Explanation | The Mainframe Connector listener has successfully activated and is waiting for incoming requests. |
System Action | None. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC113I
PSYNC113I – LISTENER SOCKET MAXIMUM IS nnn
Explanation | The Mainframe Connector listener socket maximum has been set to the value specified by ’nnn’. |
System Action | None. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC130E
PSYNC130E – Mainframe Connector LISTENER ENVIRONMENT FAILURE.
Explanation | An error occurred in the main listener task for Mainframe Connector . The main listener task is unable to communicate on the TCP/IP network. |
System Action | Mainframe Connector will attempt to re-establish communication with TCP/IP. |
Operator Response | Notify the system programmer. |
System Programmer Response | Determine if there are any problems with TCP/IP. The most likely cause of this message is that the TCP/IP stack has been terminated. If this message has been issued and the TCP/IP stack appears functional, contact Bravura Security for technical support. |
PSYNC131I
PSYNC131I – Mainframe Connector LISTENER SHUTDOWN IN PROGRESS.
Explanation | Termination of Mainframe Connector has been requested through a STOP MFC command. The Mainframe Connector listener subtask is being terminated as a result of the STOP command. |
System Action | None. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC132I
PSYNC132I – Mainframe Connector LISTENER TERMINATION OF SUBTASKS IN PROGRESS.
Explanation | Termination of Mainframe Connector has been requested through a STOP MFC command. The Mainframe Connector concurrent listener subtasks are being terminated as a result of the STOP command. |
System Action | None. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC133I
PSYNC133I – Mainframe Connector LISTENER TERMINATION OF SUBTASKS COMPLETE.
Explanation | The Mainframe Connector concurrent server listener subtasks have terminated successfully. |
System Action | None. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC141I
PSYNC141I – Mainframe Connector LISTENER TASK TERMINATION INITIATED.
Explanation | A request to stop Mainframe Connector is in progress. Shutdown processing has recognized the existence of a listener subtask environment and the associated task is being terminated. |
System Action | Mainframe Connector is terminating its subtask environment. There may be requests currently being processed for a Bravura Pass and/or Bravura Identity server. These requests will be allowed to complete or are gracefully terminated (userid or group list requests) and as a result, listener task termination may take upwards of a minute to complete. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC142I
PSYNC142I – Mainframe Connector LISTENER TASK TERMINATION COMPLETE.
Explanation | A request to stop Mainframe Connector is in progress. The listener subtask environment has been terminated. |
System Action | None. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC150W
PSYNC150W – CONNECTION TO TCP/IP STACK HAS BEEN SEVERED. ATTEMPTING LISTENER RESTART.
Explanation | The Mainframe Connector transparent listener has detected a connection loss with the TCP/IP stack and communication will attempt to be re-established. |
System Action | The Mainframe Connector transparent listener will attempt to dynamically reconnect to the TCP/IP stack. |
Operator Response | Notify the system programmer. |
System Programmer Response | Investigate the cause of the problem. The output from the Mainframe Connector subsystem should contain more information regarding the error condition. If the cause of the error cannot be determined, contact Bravura Security for technical support. |
PSYNC151E
PSYNC151E – Mainframe Connector LISTENER SERVER TASK ATTACH FAILED.
Explanation | The creation of the Mainframe Connector concurrent listener environment has failed. |
System Action | The Mainframe Connector subsystem will terminate. |
Operator Response | Attempt to restart Mainframe Connector and notify the system programmer of the error condition. |
System Programmer Response | Investigate the cause of the problem. The output from the Mainframe Connector subsystem should contain more information regarding the error condition. If the cause of the error cannot be determined, contact Bravura Security for technical support. |
PSYNC152E
PSYNC152E – Mainframe Connector LISTENER SERVER ACCEPT PROCESSING FAILED.
Explanation | The Mainframe Connector server listener process has failed. |
System Action | The Mainframe Connector subsystem will terminate. |
Operator Response | Attempt to restart Mainframe Connector and notify the system programmer of the error condition. |
System Programmer Response | Investigate the cause of the problem. The output from the Mainframe Connector subsystem should contain more information regarding the error condition. If the cause of the error cannot be determined, contact Bravura Security for technical support. |
PSYNC153E
PSYNC153E – UNRECOVERABLE FAILURE OCCURRED IN PARALLEL PROCESSING. PARALLEL PROCESSING IS TERMINATING __tsched() error nn.
Explanation | An unrecoverable error has occurred in a Mainframe Connector listener parallel function task. This error has rendered the parallel Mainframe Connector listener component inoperative. The errno value ’nn’ further describes the offending condition. |
System Action | The Mainframe Connector subsystem will not accept incoming client connection requests. |
Operator Response | Notify the system programmer of the error condition. If the problem persists, Mainframe Connector will need to be restarted. |
System Programmer Response | Investigate the cause of the problem. The output from the Mainframe Connector subsystem should contain more information regarding the error condition. If the cause of the error cannot be determined, contact Bravura Security for technical support. |
PSYNC201I
PSYNC201I – Mainframe Connector PASSWORD VALIDATION INITIATED
Explanation | A password change request has been recognized by Mainframe Connector and validation to the Bravura Pass server has been initiated. |
System Action | An attempt will be made to contact the Bravura Pass server to validate the current password change request. This message will be issued to the terminal of the user making the password change request unless the password change request is occurring in a background job. This message will be issued to the background job log in that case. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC202I
PSYNC202I – Mainframe Connector PASSWORD VALIDATION IN PROGRESS
Explanation | A password change request has been recognized by Mainframe Connector and validation from the Bravura Pass server is pending. |
System Action | An attempt has been made to contact the Bravura Pass server to validate the current password change request. This message will be issued to the terminal of the user making the password change request unless the password change request is occurring in a background job. This message will be issued to the background job log in that case. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC203I
PSYNC203I – Mainframe Connector PASSWORD VALIDATION WAS SUCCESSFUL
Explanation | A password change request has been recognized by Mainframe Connector and validation from the Bravura Pass server has indicated that the password change is appropriate. |
System Action | The Bravura Pass server has indicated that the requested password change is acceptable. The MVS security product should be allowed to make the password change. This message will be issued to the terminal of the user making the password change request unless the password change request is occurring in a background job. This message will be issued to the background job log in that case. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC204I
PSYNC204I – Mainframe Connector PASSWORD VALIDATION TIMEOUT
Explanation | A password change request has been recognized by Mainframe Connector and validation from the Bravura Pass server did not occur within the Mainframe Connector timeout limit. |
System Action | The current request to Mainframe Connector has timed out. The MVS security product will continue with the password change request. This message will be issued to the terminal of the user making the password change request unless the password change request is occurring in a background job. This message will be issued to the background job log in that case. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC205I
PSYNC205I – Mainframe Connector PASSWORD VALIDATION FAILED
Explanation | A password change request has been recognized by Mainframe Connector and the Bravura Pass server has indicated that the current password is not acceptable. |
System Action | The current password change request has failed Mainframe Connector validation. The MVS security product will fail this password change request. This message will be issued to the terminal of the user making the password change request unless the password change request is occurring in a background job. This message will be issued to the background job log in that case. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC206I
PSYNC206I – Mainframe Connector SERVER SOCKET CONNECTION FAILURE
Explanation | A password change request has been recognized by Mainframe Connector but a failure occurred in establishing the socket connection to the Bravura Pass server. |
System Action | The Mainframe Connector subsystem was unable to establish a socket connection with the Bravura Pass server. The MVS security product should proceed with the password change request. This message will be issued to the terminal of the user making the password change request unless the password change request is occurring in a background job. This message will be issued to the background job log in that case. |
Operator Response | None. |
System Programmer Response | A determination needs to be made regarding the status of the Bravura Pass server. The Bravura Pass server may be inoperative or network connectivity to the Bravura Pass server may have been severed. |
PSYNC207I
PSYNC207I – Mainframe Connector PASSWORD VALIDATION UNKNOWN FAILURE
Explanation | A password change request has been recognized by Mainframe Connector but a failure occurred in the validation process. |
System Action | An unknown failure occurred during the password validation process. The MVS security product should proceed with the password change request. This message will be issued to the terminal of the user making the password change request unless the password change request is occurring in a background job. This message will be issued to the background job log in that case. |
Operator Response | None. |
System Programmer Response | The cause of the problem needs to be investigated. This error message should rarely, if ever, be issued. If the cause of the problem cannot be determined, contact Bravura Security technical support. |
PSYNC209I
PSYNC209I – Mainframe Connector SUBSYSTEM NOT CURRENTLY ACTIVE
Explanation | A request has been make to change a password. The Mainframe Connector subsystem is not currently active and Mainframe Connector will not process this request. |
System Action | The MVS security product will continue with the password change request with no influence from Mainframe Connector . |
Operator Response | If this message is reported or detected, validate the status of the Mainframe Connector subsystem. If it is not currently active, the message has been issued appropriately. Determine if Mainframe Connector should be activated. If Mainframe Connector is active, report this condition to the system programmer for further investigation. |
System Programmer Response | If this message is issued while the Mainframe Connector subsystem is active, it is possible that the Mainframe Connector subsystem control block or function routines have become corrupted. Attempt to restart Mainframe Connector . If the problem persists, contact Bravura Security technical support for assistance. |
PSYNC300I
PSYNC300I – UNRECOGNIZED Mainframe Connector MODIFY REQUEST
Explanation | A MODIFY MFC command has been issued but the modify request is not a recognized Mainframe Connector request. |
System Action | Mainframe Connector continues normal operation. |
Operator Response | A valid modify command should be entered. |
System Programmer Response | None. |
PSYNC301I
PSYNC301I – INVALID DATA DETECTED FOR Mainframe Connector MODIFY TIMEOUT. CURRENT VALUE RETAINED
Explanation | A MODIFY MFC,TIMEOUT=nnn command has been issued but the value specified for nnn is not valid. |
System Action | Mainframe Connector continues normal operation. |
Operator Response | Re-enter the command with a valid value for nnn. Valid values for nnn are 20 – 120. |
System Programmer Response | None. |
PSYNC302I
PSYNC302I – INVALID OPTION FOR Mainframe Connector DISPLAY REQUEST
Explanation | A MODIFY MFC,D=value or MODIFY MFC,DISPLAY=value command was issued but value was not PARMS. |
System Action | Mainframe Connector continues normal operation. |
Operator Response | Re-enter the command with a valid value for value. The only valid entry for value is PARMS. |
System Programmer Response | None. |
PSYNC303I
PSYNC303I – INVALID VALUE FOR LISTENMAX. VALID VALUES ARE 1 – 99.
Explanation | A MODIFY MFC,LISTENMAX=value command was issued but value was not in the range 1 – 99. |
System Action | Mainframe Connector continues normal operation. |
Operator Response | Re-enter the command with a valid value for value. Values for value can be in the range 1 – 99. |
System Programmer Response | None. |
PSYNC304I
PSYNC304I – LISTENMAX VALUE NOT UPDATED. SPECIFIED VALUE THE SAME AS CURRENT VALUE.
Explanation | A MODIFY MFC,LISTENMAX=value command was issued but value is equal to the current LISTENMAX value. |
System Action | Mainframe Connector continues normal operation. |
Operator Response | Re-enter the command with a valid value for value that is different from the current setting. Values for value can be in the range 1 – 99. |
System Programmer Response | None. |
PSYNC305I
PSYNC305I – INVALID LISTENONLY VALUE. VALID VALUES ARE YES OR NO.
Explanation | A MODIFY MFC,LISTENONLY=value command was issued but value was not YES or NO. |
System Action | Mainframe Connector continues normal operation. |
Operator Response | Re-enter the command with a valid value for value. Valid values are YES or NO. |
System Programmer Response | None. |
PSYNC306I
PSYNC306I – INVALID LISTCHECK VALUE. VALID VALUES ARE INOUT, INBOUNDONLY, OR OUTBOUNDONLY.
Explanation | A MODIFY MFC,LISTCHECK=value command was issued but value was not INOUT, INBOUNDONLY, or OUTBOUNDONLY. |
System Action | Mainframe Connector continues normal operation. |
Operator Response | Re-enter the command with a valid value for value. Valid values are INOUT, INBOUNDONLY, or OUTBOUNDONLY. |
System Programmer Response | None. |
PSYNC307I
PSYNC307I – INVALID ENCRYPTION VALUE. VALID VALUES ARE IDEA OR AES.
Explanation | A MODIFY MFC,ENCRYPTION=value command was issued but value was not IDEA or AES. |
System Action | Mainframe Connector continues normal operation. |
Operator Response | Re-enter the command with a valid value for value. Valid values are IDEA or AES. |
System Programmer Response | None. |
PSYNC308I
PSYNC308I – INVALID ENTROPYFALLBACK VALUE. VALID VALUES ARE YES OR NO.
Explanation | A MODIFY MFC,ENTROPYFALLBACK=value command was issued but value was not YES or NO. |
System Action | Mainframe Connector continues normal operation. |
Operator Response | Re-enter the command with a valid value for value. Valid values are YES or NO. |
System Programmer Response | None. |
PSYNC309I
PSYNC309I – INVALID SOCKETCLOSEWAIT VALUE. VALID VALUES ARE 0 - 5.
Explanation | A MODIFY MFC,SOCKETCLOSEWAIT=value command has been issued but value was not a numeric in the range 0 - 5. |
System Action | The SOCKETCLOSEWAIT is left unchanged. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC310I
PSYNC310I – INVALID OUTBOUNDPWCASE VALUE. VALID VALUES ARE ASIS, LOWER, OR UPPER.
Explanation | A MODIFY MFC,OUTBOUNDPWCASE=value command has been issued but value was not ASIS, LOWER or UPPER. |
System Action | The OUTBOUNDPWCASE is left unchanged. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC311I
PSYNC311I – Mainframe Connector TIMEOUT VALUE SUCCESSFULLY RESET
Explanation | A MODIFY MFC,TIMEOUT=nnn command has been issued and the Mainframe Connector TIMEOUT value has been reset. |
System Action | The Mainframe Connector TIMEOUT value has been changed to nnn. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC312I
PSYNC312I – Mainframe Connector LISTENMAX RESET ACKNOWLEDGED.
Explanation | A MODIFY MFC,LISTENMAX=nn command has been issued and acknowledged by Mainframe Connector . |
System Action | Mainframe Connector is attempting to update internal tasks to support the new LISTENMAX value, nn. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC313I
PSYNC313I – Mainframe Connector LISTENONLY VALUE SUCCESSFULLY RESET.
Explanation | A MODIFY MFC,LISTENONLY=value command has been issued and Mainframe Connector has successfully updated the LISTENONLY status. |
System Action | Mainframe Connector has updated the LISTENONLY value to value. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC314I
PSYNC314I – Mainframe Connector LISTENMAX VALUE SUCCESSFULLY RESET.
Explanation | A MODIFY MFC,LISTENMAX=nn command has been issued and Mainframe Connector has successfully updated the LISTENMAX status. |
System Action | Mainframe Connector has updated the LISTENMAX value to nn. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC315I
PSYNC315I – ATTEMPTING PASSWORD MANAGER SERVER CONNECTION TEST.
Explanation | A MODIFY MFC,CONNECTTEST command has been issued and Mainframe Connector is attempting a handshake connection with the Bravura Pass server. |
System Action | Mainframe Connector is attempting a test connection with the Bravura Pass server. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC316I
PSYNC316I – PASSWORD MANAGER SERVER CONNECTION TEST COMPLETED SUCCESSFULLY.
Explanation | A MODIFY MFC,CONNECTTEST command has been issued and Mainframe Connector has completed a successful test connection with the Bravura Pass server. |
System Action | Mainframe Connector successfully completed a test connection with the Bravura Pass server. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC317I
PSYNC317I – Mainframe Connector LISTCHECK VALUE SUCCESSFULLY RESET.
Explanation | A MODIFY MFC,LISTCHECK=value command has been issued and Mainframe Connector has successfully updated the LISTCHECK option. |
System Action | Mainframe Connector has updated the LISTCHECK value to value. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC318I
PSYNC318I – INVALID VALUE FOR DEBUGLEVEL. VALID VALUES ARE 0 - 9.
Explanation | A MODIFY MFC,DEBUGLEVEL=value command has been issued but value was not a numeric in the range 0 - 9. |
System Action | The DEBUGLEVEL is left unchanged. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC319I
PSYNC319I – Mainframe Connector DEBUGLEVEL SUCCESSFULLY RESET.
Explanation | A MODIFY MFC,DEBUGLEVEL=value command has been issued and the Mainframe Connector DEBUGLEVEL has been reset to value. |
System Action | The DEBUGLEVEL has been changed to value. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC320I
PSYNC320I – Mainframe Connector DEBUGLEVEL LIMITED TO DEBUGMAX
Explanation | A MODIFY MFC,DEBUGLEVEL=value command has been issued and the requested value exceeds the maximum allowable value as specified in the DEBUGMAX parameter. |
System Action | The DEBUGLEVEL has been changed to the maximum value permitted by the DEBUGMAX parameter. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC321I
PSYNC321I – Mainframe Connector ENCRYPTION VALUE SUCCESSFULLY RESET.
Explanation | A MODIFY MFC,ENCRYPTION=value command has been issued and the Mainframe Connector ENCRYPTION has been reset to value. |
System Action | Mainframe Connector has updated the ENCRYPTION value to value. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC322I
PSYNC322I – Mainframe Connector ENTROPYFALLBACK VALUE SUCCESSFULLY RESET.
Explanation | A MODIFY MFC,ENTROPYFALLBACK=value command has been issued and the Mainframe Connector ENTROPYFALLBACK has been reset to value. |
System Action | Mainframe Connector has updated the ENTROPYFALLBACK value to value. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC323I
PSYNC323I – Mainframe Connector SOCKETCLOSEWAIT VALUE SUCCESSFULLY RESET.
Explanation | A MODIFY MFC,SOCKETCLOSEWAIT=value command has been issued and the Mainframe Connector SOCKETCLOSEWAIT has been reset to value. |
System Action | The SOCKETCLOSEWAIT has been changed to value. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC324I
PSYNC324I – Mainframe Connector OUTBOUNDPWCASE VALUE SUCCESSFULLY RESET.
Explanation | A MODIFY MFC,OUTBOUNDPWCASE=value command has been issued and the Mainframe Connector OUTBOUNDPWCASE has been reset to value. |
System Action | The OUTBOUNDPWCASE has been changed to value. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC330I
PSYNC330I – COMMAND SUCCESSFUL
Explanation | A request to dynamically deactivate or reactivate one of the in-storage lists (INLIST, EXLIST, or ADMINIDS) has successfully completed. |
System Action | Mainframe Connector has updated the status for the corresponding list. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC331I
PSYNC331I – ENTRY ALREADY EXISTS; NOT ADDED
Explanation | A request to dynamically add a userid or groupid entry to one of the in-storage lists (INLIST, EXLIST, or ADMINIDS) detected that the requested add entry already existed in the corresponding table. |
System Action | None. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC332I
PSYNC332I – ENTRY DOES NOT EXIST; NOT DELETED
Explanation | A request to dynamically delete a userid or groupid entry from one of the in-storage lists (INLIST, EXLIST, or ADMINIDS) detected that the requested delete entry did not exist in the corresponding table. |
System Action | None. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC333I
PSYNC333I – REQUEST DENIED - ACTIVATED STATUS NOT PERMITTED FOR INLIST AND EXLIST CONCURRENTLY
Explanation | A request to dynamically reactivate an INLIST or EXLIST detected that the opposing list was already active. |
System Action | The request is rejected. INLIST and EXLIST can not be active simultaneously. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC335I
PSYNC335I – Mainframe Connector MAXIMUM OF 32 ddname CONCATENATION DATA. DATA SETS EXCEEDED, REMAINDER IGNORED
Explanation | The DDNAME indicated by ddname has more than 32 DD statements in its concatenation. |
System Action | If a dynamic reload request is performed for the indicated DDNAME, ddname, only the first 32 DD statements will be processed. |
Operator Response | Notify the system programmer of this message. |
System Programmer Response | Assess the datasets used in the concatenation for the indicated DDNAME and attempt to limit the concatenation to 32 DD statements. If more than 32 DD statements are used, the results of dynamic reload requests will not deliver the expected results. |
PSYNC340I
PSYNC340I – TABLE NOT PRESENT
Explanation | A request to dynamically deactivate or reactivate one of the in-storage lists (INLIST, EXLIST, or ADMINIDS) has determined that the requested list does not exist. |
System Action | The requested action is bypassed. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC380I
PSYNC380I – RELOAD REQUESTED.
Explanation | A request has been made to reload one of the in-storage lists (INLIST, EXLIST, or ADMINIDS) from the JCL defined datasets. |
System Action | Mainframe Connector will attempt to create an updated in-storage list from the JCL defined datasets. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC381I
PSYNC381I – RELOAD SUCCESSFUL.
Explanation | A request has been made to reload one of the in-storage lists (INLIST, EXLIST, or ADMINIDS) from the JCL defined datasets and the request has successfully completed. |
System Action | Mainframe Connector has created an updated in-storage list from the JCL defined datasets. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC382I
PSYNC382I – DD FOR REQUESTED TABLE IGNORED OR NOT INCLUDED IN STARTUP JCL
Explanation | A request has been made to reload one of the in-storage lists (INLIST, EXLIST, or ADMINIDS) from the JCL defined datasets and the requested DDNAME did not exist in the startup JCL or an opposing list is already active. |
System Action | Mainframe Connector rejects the request. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC383I
PSYNC383I – RELOAD FAILED.
Explanation | A request has been made to reload one of the in-storage lists (INLIST, EXLIST, or ADMINIDS) from the JCL defined datasets and the request failed to complete successfully. |
System Action | Mainframe Connector rejects the request. |
Operator Response | Notify the system programmer. |
System Programmer Response | The most likely cause of a reload failure would be a problem in dynamic allocation. Determine if message PSYNC385E has also been issued and if so, check the dynamic allocation error codes in the message. If you are unable to determine the cause of the reload failure, contact Bravura Security technical support for assistance. |
PSYNC385E
PSYNC385E – ftype FAILURE ERROR=errcd INFO=infcd
Explanation | A dynamic allocation error has occurred. The request type ftype indicates the type of the request. If ftype is PALLOC, this indicates that a failure occurred attempting to allocate a member of a PDS. If ftype is FALLOC, this indicates that a failure occurred attempting to allocate a sequential dataset. If ftype is CALLOC, this indicates that a failure occurred attempting to concatenate a dataset into a DDNAME allocation. If ftype is UALLOC, this indicates that a failure occurred unallocating a DDNAME. The value in errcd and infcd provide information regarding the nature of the dynamic allocation failure. |
System Action | Mainframe Connector rejects the request. |
Operator Response | Notify the system programmer. |
System Programmer Response | This condition is unexpected. Contact Bravura Security technical support for assistance. |
PSYNC386I
PSYNC386I – ENTRY ADDED.
Explanation | A request has been made to add an entry to one of the in-storage lists (INLIST, EXLIST, or ADMINIDS) and the request has successfully completed. |
System Action | Mainframe Connector has created an updated in-storage list that includes the add request entry. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC387I
PSYNC387I – ENTRY DELETED.
Explanation | A request has been made to delete an entry from one of the in-storage lists (INLIST, EXLIST, or ADMINIDS) and the request has successfully completed. |
System Action | Mainframe Connector has created an updated in-storage list that removes the delete request entry. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC388E
PSYNC388E – ENTRY NOT ADDED.
Explanation | A request has been made to add an entry to one of the in-storage lists (INLIST, EXLIST, or ADMINIDS) and an environment problem prevented the entry from being added. |
System Action | Mainframe Connector has not updated the specified in-storage list. |
Operator Response | Notify the system programmer. |
System Programmer Response | Mainframe Connector is most probably experiencing a storage availability problem. If the cause of the problem can not be determined, contact Bravura Security technical support for assistance. |
PSYNC389E
PSYNC389E – ENTRY NOT DELETED.
Explanation | A request has been made to delete an entry from one of the in-storage lists (INLIST, EXLIST, or ADMINIDS) and an environment problem prevented the entry from being deleted. |
System Action | Mainframe Connector has not updated the specified in-storage list. |
Operator Response | Notify the system programmer. |
System Programmer Response | Mainframe Connector is most probably experiencing a storage availability problem. If the cause of the problem can not be determined, contact Bravura Security technical support for assistance. |
PSYNC390I
PSYNC390I – ADD/DEL FORMAT ERROR.
Explanation | A request has been made to update one of the in-storage lists (INLIST, EXLIST, or ADMINIDS) but the format of the ADD/DEL request is invalid. |
System Action | None. |
Operator Response | Notify the system programmer. |
System Programmer Response | Mainframe Connector Operator Commands provides examples of the correct syntax for ADD/DEL requests. |
PSYNC395I
PSYNC395I – RELOAD COMMAND FORMAT ERROR.
Explanation | A request has been made to reload one of the in-storage lists (INLIST, EXLIST, or ADMINIDS) from the JCL defined datasets but a valid DDNAME could not be determined. |
System Action | None. |
Operator Response | Notify the system programmer. |
System Programmer Response | Mainframe Connector Operator Commands provides examples of the correct syntax for RELOAD requests. Valid DDNAME’s are INLIST, EXLIST, and ADMINIDS. |
PSYNC491E
PSYNC491E –ABEND xxx DETECTED DURING Mainframe Connector PSNCCMDM PROCESSING.
Explanation | An abend xxx occurred in the PSNCCMDM subtask. |
System Action | Mainframe Connector will attempt to recover. If recovery is successful, Mainframe Connector will continue with normal operation. If recovery is not successful, Mainframe Connector will need to be terminated and restarted. |
Operator Response | None. |
System Programmer Response | The cause of the abend should be investigated. |
PSYNC493E
PSYNC493E –ABEND xxx DETECTED DURING Mainframe Connector PSNCLDRV PROCESSING.
Explanation | An abend xxx occurred in the PSNCLDRV subtask. |
System Action | Mainframe Connector will attempt to recover. If recovery is successful, Mainframe Connector will continue with normal operation. If recovery is not successful, Mainframe Connector will need to be terminated and restarted. |
Operator Response | None. |
System Programmer Response | The cause of the abend should be investigated. |
PSYNC501E
PSYNC501E –ERROR OBTAINING WORKING STORAGE FOR PSNCCMDM. PROCESSING TERMINATED
Explanation | PSNCCMDM was unable to obtain local working storage. |
System Action | Mainframe Connector command processing is terminated. |
Operator Response | An attempt should be made to terminate the current Mainframe Connector subsystem. After the current subsystem is terminated, Mainframe Connector should be restarted. Notify the system programmer of the error. |
System Programmer Response | Examine Mainframe Connector job log and dump to determine the storage obtain problem. |
PSYNC503E
PSYNC503E –ERROR OBTAINING WORKING STORAGE FOR PSNCLDRV. PROCESSING TERMINATED
Explanation | PSNCLDRV was unable to obtain local working storage. |
System Action | Mainframe Connector command processing is terminated. |
Operator Response | An attempt should be made to terminate the current Mainframe Connector subsystem. After the current subsystem is terminated, Mainframe Connector should be restarted. Notify the system programmer of the error. |
System Programmer Response | Examine Mainframe Connector job log and dump to determine the storage obtain problem. |
PSYNC521E
PSYNC521E – ERROR OBTAINING WORKING STORAGE FOR PSNCT254. PROCESSING TERMINATED
Explanation | PSNCT254 was unable to obtain local working storage. |
System Action | Mainframe Connector function routine subtask processing is terminated. |
Operator Response | None. |
System Programmer Response | Examine Mainframe Connector job log and dump to determine the storage obtain problem. |
PSYNC522E
PSYNC522E –ABEND xxx DETECTED DURING Mainframe Connector PSNCT254 PROCESSING.
Explanation | An abend xxx occurred in the PSNCT254 subtask. A z/OS password change event was in progress and password synchronization may not have been successfully performed if this message has been issued. |
System Action | Mainframe Connector will attempt to recover. If recovery is successful, Mainframe Connector will continue with normal operation. If recovery is not successful, Mainframe Connector will need to be terminated and restarted. |
Operator Response | None. |
System Programmer Response | The cause of the abend should be investigated. |
PSYNC551I
PSYNC551I – AUDIT DATASET IS FULL. LOGGING HAS BEEN DISABLED
Explanation | An entry was being written to the AUDIT dataset but the dataset is full. |
System Action | Mainframe Connector continues to function with AUDIT disabled. |
Operator Response | None. |
System Programmer Response | The current log information should be captured and saved. A new log dataset should be allocated (or a JES spooled dataset should be used) and Mainframe Connector should be restarted. |
PSYNC552E
PSYNC552E – AUDIT I/O ERROR. LOGGING FUNCTION HAS BEEN DISABLED
Explanation | An entry was being written to the AUDIT dataset but an I/O error occurred during the write operation. |
System Action | Mainframe Connector continues to function with AUDIT disabled. |
Operator Response | None. |
System Programmer Response | The current log information should be captured and saved. A new log dataset should be allocated (or a JES spooled dataset should be used) and Mainframe Connector should be restarted. |
PSYNC553I
PSYNC553I – SYNCHLOG DATASET IS FULL. LOGGING HAS BEEN DISABLED
Explanation | An entry was being written to the SYNCHLOG dataset but the dataset is full. |
System Action | Mainframe Connector continues to function with SYNCHLOG logging disabled. |
Operator Response | None. |
System Programmer Response | The current log information should be captured and saved. A new log dataset should be allocated (or a JES spooled dataset should be used) and Mainframe Connector should be restarted. |
PSYNC554E
PSYNC554E – SYNCHLOG I/O ERROR. LOGGING FUNCTION HAS BEEN DISABLED
Explanation | An entry was being written to the SYNCHLOG dataset but an I/O error occurred during the write operation. |
System Action | Mainframe Connector continues to function with SYNCHLOG logging disabled. |
Operator Response | None. |
System Programmer Response | The current log information should be captured and saved. A new log dataset should be allocated (or a JES spooled dataset should be used) and Mainframe Connector should be restarted. |
PSYNC600E
PSYNC600E – LABEL label: message [R15=X’r15’] [R0=X’r0’]
Explanation | Dataspace creation or logging encountered an error. Where: label identifies the source code location of the error message is one of the following: ’TCBTOKEN’ ERROR - DATASPACE NOT CREATED DSPSERV CREATE’ ERROR - DATASPACE NOT CREATED ’ALESERV ADD’ ERROR - DATASPACE NOT CREATED INVALID REQUEST CODE INVALID RECORD TYPE INVALID RECORD LENGTH r15 and r0 are the respective contents of the return and reason code registers |
System Action | Dataspace creation does not proceed and/or logging is disabled. |
Operator Response | Report the condition to the system programmer. |
System Programmer Response | If no other preceding or accompanying Mainframe Connector or system conditions exist which might explain the error, contact Bravura Security technical support for assistance. |
PSYNC600I
PSYNC600I – LABEL label: Dataspace successfully established R15=X’00000000’ R0=X’00000000’
Explanation | An event occurred for which dataspace logging had been requested. The dataspace has been successfully established. |
System Action | The event is logged to the dataspace. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC725E
PSYNC725E – FAILURE xxxxxxxx INITIATING COMMAND SUBTASK. Mainframe Connector IS TERMINATING.
Explanation | Attaching the PSNCCMDM subtask resulted in a xxxxxxxx failure. |
System Action | Mainframe Connector terminates. |
Operator Response | Attempt to restart Mainframe Connector . If the problem persists, contact the system programmer. |
System Programmer Response | Determine the cause of the xxxxxxxx failure. If the problem cannot be resolved, contact Bravura Security technical support. |
PSYNC726E
PSYNC726E – FAILURE xxxxxxxx INITIATING LISTENER SUBTASK. Mainframe Connector IS TERMINATING.
Explanation | Attaching the PSNCLDRV subtask resulted in a xxxxxxxx failure. |
System Action | Mainframe Connector terminates. |
Operator Response | Attempt to restart Mainframe Connector . If the problem persists, contact the system programmer. |
System Programmer Response | Determine the cause of the xxxxxxxx failure. If the problem cannot be resolved, contact Bravura Security technical support. |
PSYNC751I
PSYNC751I– CHECK INLIST DATASET RECORD nnnn FOR INVALID DATA.
Explanation | The dataset specified in the INLIST DD contains an invalid include list control card in record nnnn. |
System Action | Mainframe Connector continues processing with the next INLIST control card. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | Check record nnnn in the INLIST dataset. Valid control cards for include list processing are INCLUDEUSER=username and INCLUDEGROUP=grpname. |
PSYNC752I
PSYNC752I– CHECK EXLIST DATASET RECORD nnnn FOR INVALID DATA.
Explanation | The dataset specified in the EXLIST DD contains an invalid exclude list control card in record nnnn. |
System Action | Mainframe Connector continues processing with the next EXLIST control card. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | Check record nnnn in the EXLIST dataset. Valid control cards for exclude list processing are EXCLUDEUSER=username and EXCLUDEGROUP=grpname. |
PSYNC861W
PSYNC861W – DEBUGLEVEL PARAMETER RECORD ALREADY PROCESSED.
Explanation | PARMLIB dataset parameter validation has detected a DEBUGLEVEL parameter statement after a prior valid DEBUGLEVEL statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC862E
PSYNC862E – INVALID DATA DETECTED FOR DEBUGLEVEL. VALID VALUES ARE 0 - 9.
Explanation | PARMLIB dataset parameter validation has detected invalid data for a DEBUGLEVEL parameter statement. Valid data for DEBUGLEVEL is numeric in the range 0 - 9. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate value for DEBUGLEVEL. |
PSYNC863W
PSYNC863W – DATASPACE PARAMETER RECORD ALREADY PROCESSED.
Explanation | PARMLIB dataset parameter validation has detected a DATASPACE parameter statement after a prior valid DATASPACE statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC864E
PSYNC864E – INVALID, MISSING, OR REDUNDANT DATA DETECTED FOR DATASPACE - DATASPACE LOGGING DISABLED.
Explanation | PARMLIB dataset parameter validation detected at least one error condition in the DATASPACE parameter values. Valid parameter values for DATASPACE are SMF, AUDIT, SYNCHLOG, nnnnn where ’nnnnn’ is a decimal number between 1 and 524,288. Dataspace logging will not be enabled. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include appropriate values for DATASPACE. |
PSYNC865W
PSYNC865W – RESETAUTH PARAMETER RECORD ALREADY PROCESSED.
Explanation | PARMLIB dataset parameter validation has detected a RESETAUTH parameter statement after a prior valid RESETAUTH statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC866E
PSYNC866E – INVALID DATA DETECTED FOR RESETAUTH.
Explanation | PARMLIB dataset parameter validation has detected invalid data for a RESETAUTH parameter statement. Valid values for RESETAUTH are APF or STCID. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate value for RESETAUTH. |
PSYNC867W
PSYNC867W – REPORTSYSID PARAMETER RECORD ALREADY PROCESSED.
Explanation | PARMLIB dataset parameter validation has detected a REPORTSYSID parameter statement after a prior valid REPORTSYSID statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC868E
PSYNC868E – INVALID DATA DETECTED FOR REPORTSYSID.
Explanation | PARMLIB dataset parameter validation has detected invalid data for a REPORTSYSID parameter statement. Valid values for REPORTSYSID are YES or NO. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate value for REPORTSYSID. |
PSYNC869W
PSYNC869W – DEBUGMAX PARAMETER RECORD ALREADY PROCESSED.
Explanation | PARMLIB dataset parameter validation has detected a DEBUGMAX parameter statement after a prior valid DEBUGMAX statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC870E
PSYNC870E – INVALID DATA DETECTED FOR DEBUGMAX. VALID VALUES ARE 0 - 9.
Explanation | PARMLIB dataset parameter validation has detected invalid data for a DEBUGMAX parameter statement. Valid data for DEBUGMAX is numeric in the range 0 - 9. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate value for DEBUGMAX. |
PSYNC871W
PSYNC871W – KEYDISPLAY PARAMETER RECORD ALREADY PROCESSED.
Explanation | PARMLIB dataset parameter validation has detected a KEYDISPLAY parameter statement after a prior valid KEYDISPLAY statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC872E
PSYNC872E – INVALID DATA DETECTED FOR KEYDISPLAY.
Explanation | PARMLIB dataset parameter validation has detected invalid data for a KEYDISPLAY parameter statement. Valid values for KEYDISPLAY are ASIS or MASK. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate value for KEYDISPLAY. |
PSYNC873W
PSYNC873W – KEYENCRYPT PARAMETER RECORD ALREADY PROCESSED.
Explanation | PARMLIB dataset parameter validation has detected a KEYENCRYPT parameter statement after a prior valid KEYENCRYPT statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC874E
PSYNC874E – INVALID DATA DETECTED FOR KEYENCRYPT.
Explanation | PARMLIB dataset parameter validation has detected invalid data for a KEYENCRYPT parameter statement. Valid values for KEYENCRYPT are YES or NO. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate value for KEYENCRYPT. |
PSYNC875W
PSYNC875W – ENCRYPTION PARAMETER RECORD ALREADY PROCESSED.
Explanation | PARMLIB dataset parameter validation has detected a ENCRYPTION parameter statement after a prior valid ENCRYPTION statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC876E
PSYNC876E – INVALID DATA DETECTED FOR ENCRYPTION.
Explanation | PARMLIB dataset parameter validation has detected invalid data for an ENCRYPTION parameter statement. Valid values for ENCRYPTION are IDEA or AES. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate value for ENCRYPTION. |
PSYNC877W
PSYNC877W – ENTROPYFALLBACK PARAMETER RECORD ALREADY PROCESSED.
Explanation | PARMLIB dataset parameter validation has detected an ENTROPYFALLBACK parameter statement after a prior valid ENTROPYFALLBACK statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC878E
PSYNC878E – INVALID DATA DETECTED FOR ENTROPYFALLBACK.
Explanation | PARMLIB dataset parameter validation has detected invalid data for an ENTROPYFALLBACK parameter statement. Valid values for ENTROPYFALLBACK are YES or NO. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate value for ENTROPYFALLBACK. |
PSYNC879W
PSYNC879W – SOCKETCLOSEWAIT PARAMETER RECORD ALREADY PROCESSED.
Explanation | PARMLIB dataset parameter validation has detected a SOCKETCLOSEWAIT parameter statement after a prior valid SOCKETCLOSEWAIT statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC880E
PSYNC880E – INVALID DATA DETECTED FOR SOCKETCLOSEWAIT. VALID VALUES ARE 0 - 5.
Explanation | PARMLIB dataset parameter validation has detected invalid data for an SOCKETCLOSEWAIT parameter statement. Valid data for SOCKETCLOSEWAIT is numeric in the range 0 - 5. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate value for SOCKETCLOSEWAIT. |
PSYNC881W
PSYNC881W – OUTBOUNDPWCASE PARAMETER RECORD ALREADY PROCESSED.
Explanation | PARMLIB dataset parameter validation has detected an OUTBOUNDPWCASE parameter statement after a prior valid OUTBOUNDPWCASE statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC882E
PSYNC882E – INVALID DATA DETECTED FOR OUTBOUNDPWCASE.
Explanation | PARMLIB dataset parameter validation has detected invalid data for an OUTBOUNDPWCASE parameter statement. Valid values for OUTBOUNDPWCASE are ASIS, LOWER, or UPPER. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate value for OUTBOUNDPWCASE. |
PSYNC883W
PSYNC883W – USERIDFASTEL PARAMETER RECORD ALREADY PROCESSED.
Explanation | PARMLIB dataset parameter validation has detected a USERIDFASTDEL parameter statement after a prior valid USERIDFASTDEL statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC884E
PSYNC884E – INVALID DATA DETECTED FOR USERIDFASTDEL.
Explanation | PARMLIB dataset parameter validation has detected invalid data for a USERIDFASTDEL parameter statement. Valid values for USERIDFASTDEL are YES or NO. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate value for USERIDFASTDEL. |
PSYNC885E
PSYNC885E – INVALID DATA DETECTED FOR TSSTARGET. VALID VALUES ARE ’=’ AND ’*’.
Explanation | PARMLIB dataset parameter validation has detected invalid data for a TSSTARGET parameter statement. Valid values for TSSTARGET are = or *. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate value for TSSTARGET. |
PSYNC890I
PSYNC890I – Mainframe Connector ERROR ROUTINE REVIEWING OUTSTANDING EVENT CONDITIONS
Explanation | An abend has occurred in the Mainframe Connector subsystem address space. The ESTAE recovery routine is determining whether any outstanding events are currently active. |
System Action | The ESTAE routine will check outstanding event conditions. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC891I
PSYNC891I – Mainframe Connector POSTING OUTSTANDING EVENT 254 CONDITION
Explanation | An abend has occurred in the Mainframe Connector subsystem address space. The ESTAE recovery routine has determined that there is an active function routine. |
System Action | The ESTAE routine will post the outstanding function routine WAIT ECB. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC892E
PSYNC892E – ABEND xxx DETECTED DURING Mainframe Connector DRIVER ROUTINE. SUBSYSTEM IS DISABLED.
Explanation | An abend xxx occurred in the Mainframe Connector driver task. |
System Action | Mainframe Connector is terminated. |
Operator Response | An attempt to restart Mainframe Connector should be made. |
System Programmer Response | The cause of the abend should be investigated. |
PSYNC900E
PSYNC900E – Mainframe Connector SUBSYSTEM ssss ALREADY ACTIVE
Explanation | An attempt has been made to start a Mainframe Connector subsystem address space but a Mainframe Connector subsystem address space with subsystem name ssss is already active. |
System Action | The second Mainframe Connector subsystem address space using subsystem name ssss is terminated. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC901E
PSYNC901E – ERROR PROCESSING Mainframe Connector INITIALIZATION PARAMETERS
Explanation | Mainframe Connector subsystem address space initialization detected a problem with the specified initialization parameters. The parameters specified in the PARMLIB dataset are incomplete or in error. |
System Action | The Mainframe Connector subsystem address space is terminated. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | Examine earlier startup message to determine the problem parameter. The PARMLIB dataset must contain a parameter value for DNS, TCPPORT#, KEY, and SUBSYSNAME. |
PSYNC902W
PSYNC902W – UNRECOGNIZED INPUT PARAMETER DETECTED
Explanation | PARMLIB dataset parameter validation detected an unrecognized parameter value. Run-time parameters discusses valid parameter values. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | Determine the statement that is in error and make appropriate changes. |
PSYNC903W
PSYNC903W – DNS PARAMETER RECORD ALREADY PROCESSED
|
|
|
|
|
|
|
|
PSYNC904W
PSYNC904W – TCPPORT# PARAMETER RECORD ALREADY PROCESSED
Explanation | PARMLIB dataset parameter validation has detected a TCPPORT# parameter statement after a prior valid TCPPORT# statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC905W
PSYNC905W – KEY PARAMETER RECORD ALREADY PROCESSED
Explanation | PARMLIB dataset parameter validation has detected a KEY parameter statement after a prior valid KEY statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC906W
PSYNC906W – SUBSYSNAME PARAMETER RECORD ALREADY PROCESSED
Explanation | PARMLIB dataset parameter validation has detected a SUBSYSNAME parameter statement after a prior valid SUBSYSNAME statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC907W
PSYNC907W – TIMEOUT PARAMETER RECORD ALREADY PROCESSED
Explanation | PARMLIB dataset parameter validation has detected a TIMEOUT parameter statement after a prior valid TIMEOUT statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC908W
PSYNC908W – HOSTID PARAMETER RECORD ALREADY PROCESSED
Explanation | PARMLIB dataset parameter validation has detected a HOSTID parameter statement after a prior valid HOSTID statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC909W
PSYNC909W – LISTENPORT# PARAMETER RECORD ALREADY PROCESSED
Explanation | PARMLIB dataset parameter validation has detected a LISTENPORT# parameter statement after a prior valid LISTENPORT# statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC910W
PSYNC910W – LISTENMAX PARAMETER RECORD ALREADY PROCESSED
Explanation | PARMLIB dataset parameter validation has detected a LISTENMAX parameter statement after a prior valid LISTENMAX statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC911E
PSYNC911E – INVALID DATA DETECTED FOR TCPPORT#
Explanation | PARMLIB dataset parameter validation has detected invalid data for a TCPPORT# parameter statement. Valid data for TCPPORT# is a numeric value in the range 1–65535. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to an appropriate value within the acceptable range. |
PSYNC912E
PSYNC912E – INVALID DATA DETECTED FOR KEY
Explanation | PARMLIB dataset parameter validation has detected invalid data for a KEY parameter statement. Valid data for KEY is 32 hexadecimal characters (0-9 and A-F). See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to an appropriate value within the defined criteria. |
PSYNC913E
PSYNC913E – INVALID DATA DETECTED FOR SUBSYSTEM NAME
Explanation | PARMLIB dataset parameter validation has detected invalid data for a SUBSYSNAME parameter statement. Valid data for SUBSYSNAME must not exceed four bytes in length. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to an appropriate value within the defined criteria. |
PSYNC914E
PSYNC914E – INVALID DATA DETECTED FOR TIMEOUT VALUE. VALID DATA IS NUMERIC IN THE RANGE 20 - 120
Explanation | PARMLIB dataset parameter validation has detected invalid data for a TIMEOUT parameter statement. Valid data for TIMEOUT is numeric in the range 20–120.See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to an appropriate value within the acceptable range. |
PSYNC915E
PSYNC915E – NO VALUE SPECIFIED FOR DNS PARAMETER
Explanation | PARMLIB dataset parameter validation has detected no data for a DNS parameter statement. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate DNS value. |
PSYNC916E
PSYNC916E – NO VALUE SPECIFIED FOR HOSTID PARAMETER
Explanation | PARMLIB dataset parameter validation has detected no data for a HOSTID parameter statement. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate DNS value. |
PSYNC917E
PSYNC917E – INVALID DATA DETECTED FOR LISTENPORT#
Explanation | PARMLIB dataset parameter validation has detected invalid data for a LISTENPORT# parameter statement. Valid data for LISTENPORT# is a numeric value in the range 1–65535. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to an appropriate value within the acceptable range. |
PSYNC918E
PSYNC918E – INVALID DATA DETECTED FOR LISTENMAX.
Explanation | PARMLIB dataset parameter validation has detected no data for a LISTENMAX parameter statement. Valid data for LISTENMAX is a numeric in the range 1–99. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate DNS value. |
PSYNC921E
PSYNC921E – ALL REQUIRED Mainframe Connector PARAMETERS NOT LOCATED
Explanation | The parameters specified in the PARMLIB dataset are incomplete or in error. Parameter initialization statements must exist for DNS, TCPPORT#, KEY, SUBSYSNAME, and LISTENPORT#. |
System Action | Mainframe Connector startup will be terminated. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | Examine the PARMLIB dataset to determine the missing parameter values. |
PSYNC931I
PSYNC931I – NO VALID TIMEOUT RECORD DETECTED. DEFAULT TIMEOUT VALUE OF 20 SECONDS IN EFFECT
Explanation | Parameter processing detected no TIMEOUT parameter. A default network timeout value of 20 seconds has been activated. |
System Action | Mainframe Connector startup will continue. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | If a TIMEOUT value greater than 20 seconds is required, a parameter statement should be included in the PARMLIB dataset. |
PSYNC932I
PSYNC932I – CHECK PARAMETER DATASET RECORD nnnn FOR INVALID DATA
Explanation | Parameter processing detected invalid data for PARMLIB dataset record nnnn. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | Examine PARMLIB dataset record nnnn to determine the cause of the error. |
PSYNC933I
PSYNC933I – Mainframe Connector PARAMETER VALUES IN EFFECT:
DNS : cccccccccccccccccccccccccccccccccccccccccc
TCP PORT# : nnnnn
KEY : xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
SUBSYSTEM NAME: cccc
HOSTID : cccccccccccccccccccccccccccccccccccccccccc
LISTEN PORT# : nnnnn
LISTEN SRVRMAX: nn
ADMIN ID : ccccccc
SMF Record# : nnn
TIMEOUT : nnn Seconds
PASSIVESTART : ccc
LISTENONLY : ccc
DEBUGLEVEL : n
INLIST table : ssssssss
EXLIST table : ssssssss
ADMINIDS table: ssssssss
Dataspace : ssssssss
RESETAUTH : ccccc
REPORTSYSID : ccc
DEBUGMAX : n
KEYENCRYPT : ccc
KEYDISPLAY : cccc
ENCRYPTION : cccc
ENTROPYFALLBK : ccc
SOCKETCLOSEWT : n
OUTBOUNDPWCASE: cccc
USERIDFASTDEL : ccc
TSSTARGET : c
Explanation | The values indicated in the message were specified in the PARMLIB dataset parameter initialization statements or represent the status of the indicated influence tables. |
System Action | None. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC934I
PSYNC934I – Mainframe Connector PARAMETER VALUES IN EFFECT:
DNS : cccccccccccccccccccccccccccccccccccccccccc
TCP PORT# : nnnnn
KEY : xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
SUBSYSTEM NAME: cccc
HOSTID : cccccccccccccccccccccccccccccccccccccccccc
LISTEN PORT# : nnnnn
LISTEN SRVRMAX: nn
ADMIN ID : ccccccc
SMF Record# : nnn
TIMEOUT : nnn Seconds
PASSIVESTART : ccc
LISTENONLY : ccc
DEBUGLEVEL : n
INLIST table : ssssssss
EXLIST table : ssssssss
ADMINIDS table: ssssssss
Dataspace : ssssssss
RESETAUTH : ccccc
REPORTSYSID : ccc
DEBUGMAX : n
KEYENCRYPT : ccc
KEYDISPLAY : cccc
ENCRYPTION : cccc
ENTROPYFALLBK : ccc
SOCKETCLOSEWT : n
OUTBOUNDPWCASE: cccc
USERIDFASTDEL : ccc
TSSTARGET : c
Explanation | The values indicated in the message are the current values in effect. They may differ from the startup values as a result of dynamic changes to the environment. |
System Action | None. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC941W
PSYNC941W – SMFREC PARAMETER RECORD ALREADY PROCESSED
Explanation | PARMLIB dataset parameter validation has detected a SMFREC parameter statement after a prior valid SMFREC statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC942E
PSYNC942E – INVALID DATA DETECTED FOR SMFREC.
Explanation | PARMLIB dataset parameter validation has detected invalid data for a SMFREC parameter statement. Valid data for SMFREC is a numeric in the range 200–255. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate value for SMFREC. |
PSYNC943W
PSYNC943W – PASSIVESTART PARAMETER RECORD ALREADY PROCESSED.
Explanation | PARMLIB dataset parameter validation has detected a PASSIVESTART parameter statement after a prior valid PASSIVESTART statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC944E
PSYNC944E – INVALID DATA DETECTED FOR PASSIVESTART.
Explanation | PARMLIB dataset parameter validation has detected invalid data for a PASSIVESTART parameter statement. Valid data for PASSIVESTART is YES or NO. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate value for PASSIVESTART. |
PSYNC945W
PSYNC945W – LISTENONLY PARAMETER RECORD ALREADY PROCESSED.
Explanation | PARMLIB dataset parameter validation has detected a LISTENONLY parameter statement after a prior valid LISTENONLY statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC946E
PSYNC946E – INVALID DATA DETECTED FOR LISTENONLY.
Explanation | PARMLIB dataset parameter validation has detected invalid data for a LISTENONLY parameter statement. Valid data for LISTENONLY is YES or NO. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate value for LISTENONLY. |
PSYNC947W
PSYNC947W – LISTCHECK PARAMETER RECORD ALREADY PROCESSED.
Explanation | PARMLIB dataset parameter validation has detected a LISTCHECK parameter statement after a prior valid LISTCHECK statement has already been processed. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The redundant parameter statement should be removed from the initialization parameter dataset. |
PSYNC948E
PSYNC948E – INVALID DATA DETECTED FOR LISTCHECK.
Explanation | PARMLIB dataset parameter validation has detected invalid data for a LISTCHECK parameter statement. Valid data for LISTCHECK is INOUT, INBOUNDONLY, or OUTBOUNDONLY. See message PSYNC932I for more information. |
System Action | Parameter validation continues with the next PARMLIB statement. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The parameter should be changed to include an appropriate value for LISTCHECK. |
PSYNC949I
PSYNC949I – PREVIOUS SUBSYSTEM TERMINATION LEFT SUBSYSTEM IN ACTIVE STATUS
Explanation | Mainframe Connector subsystem address space initialization has determined that a previous copy of the Mainframe Connector subsystem was active and did not perform proper cleanup. |
System Action | Mainframe Connector will clean up the remnants of the previous subsystem address space. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | Determine why the previous Mainframe Connector address space termination did not do proper cleanup. If no determination can be made as to the cause of the improper cleanup, contact Bravura Security technical support for further assistance. |
PSYNC950E
PSYNC950E – SUBSYSTEM cccc ALREADY IN USE. jobname IS TERMINATING
Explanation | Mainframe Connector subsystem address space initialization has determined that the subsystem name specified in the SUBSYSNAME initialization parameter is already in use by another subsystem. jobname is the name of the Mainframe Connector address space that is attempting initialization |
System Action | Mainframe Connector startup will terminate. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | The subsystem name specified in the SUBSYSNAME initialization parameter must be unique. Make sure that no other subsystems currently use the subsystem name that is to be used for Mainframe Connector . |
PSYNC951I
PSYNC951I – PREVIOUS SSVT ADDRESS USED FOR Mainframe Connector ACTIVATION
Explanation | Mainframe Connector subsystem address space initialization has determined that a previous SSVT can be used for this startup. |
System Action | Mainframe Connector continues with initialization. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC952I
PSYNC952I – Mainframe Connector SSCVT NOT FOUND. DYNAMIC BUILD WILL BE ATTEMPTED
Explanation | Mainframe Connector subsystem address space initialization has determined that an SSCVT entry for the subsystem name specified on the SUBSYSNAME initialization parameter statement does not exist in the MVS SSCVT chain. |
System Action | Mainframe Connector will attempt to format a new SSCVT entry and insert it into the current SSCVT chain. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC953E
PSYNC953E – Mainframe Connector SSCVT STORAGE OBTAIN FAILURE. Mainframe Connector SUBSYSTEM TERMINATING
Explanation | Mainframe Connector subsystem address space initialization has determined that an SSCVT entry for the subsystem name specified on the SUBSYSNAME initialization parameter statement does not exist in the MVS SSCVT chain. An attempt has been made to dynamically add an SSCVT entry but the attempt to obtain the common area storage required for the SSCVT has failed. |
System Action | Mainframe Connector startup will terminate. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | Determine if there are any issues with common storage availability, specifically subpool 241. If no issues exist and the problem persists, contact Bravura Security technical support for assistance. |
PSYNC957I
PSYNC957I – Resource manager setup using existing PSNCRMGR at X’xxxxxxxx’
Explanation | The resource manager setup routine determined that an existing PSNCRMGR at address xxxxxxxx would satisfy requirements for this instance of Mainframe Connector . |
System Action | Mainframe Connector resource manager initialization continues. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC958I
PSYNC958I – Resource manager setup loading new PSNCRMGR at X’xxxxxxxx’
Explanation | The resource manager setup routine is loading a new PSNCRMGR at address xxxxxxxx to satisfy requirements for this instance of Mainframe Connector . |
System Action | Mainframe Connector resource manager initialization continues. |
Operator Response | None. |
System Programmer Response | None. |
PSYNC959E
PSYNC959E – Resource manager setup xxxxxxxx operation failed with return code X’xx’
Explanation | The resource manager setup routine encountered a failure while performing operation xxxxxxxx. The return code from the operation was xx. |
System Action | Mainframe Connector resource manager setup is discontinued, however, Mainframe Connector system initialization proceeds. In the absence of any further errors, the remainder of system initialization and operation should be unaffected. In the event of subsequent Mainframe Connector abnormal termination of this instance, resource cleanup may be incomplete. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | An unexpected condition has occurred with the Mainframe Connector started task. If you are unable to determine the cause of the return code indicated by ’xx’, contact Bravura Security technical support for assistance. |
PSYNC960E
PSYNC960E – UNABLE TO ESTABLISH COMMUNICATION WITH PASSWORD/ID MANAGER SERVER. Mainframe Connector SUBSYSTEM TERMINATING.
Explanation | Mainframe Connector subsystem address space initialization has attempted a connectivity test with the Bravura Security Fabric server. The Mainframe Connector subsystem was unable to contact the Bravura Security Fabric server. |
System Action | Mainframe Connector startup will terminate. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | A number of factors can contribute to this condition. The DNS, TCPPORT#, and KEY values should all be checked to verify their accuracy. The Bravura Security Fabric server should be checked to determine if it is available. There must be an available TCP/IP network path between this MVS system and the Bravura Security Fabric server. |
PSYNC961W
PSYNC961W – CONNECT TO PASSWORD/ID MANAGER SERVER FAILED.
Explanation | An attempt was made to establish a dialogue with the Bravura Security Fabric server but the Bravura Security Fabric server did not respond to the request. |
System Action | The active request will terminate. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | A number of factors can contribute to this condition. The DNS, TCPPORT#, and KEY values should all be checked to verify their accuracy. The Bravura Security Fabric server should be checked to determine if it is available. The pushpass service must be installed and active on the Bravura Security Fabric server. There must be an available TCP/IP network path between this MVS system and the Bravura Security Fabric server. If you are unable to determine the cause of the message, contact Bravura Security technical support for assistance. |
PSYNC962W
PSYNC962W – COMMUNICATION WITH THE PASSWORD MANAGER SERVER TIMED OUT.
Explanation | A socket connection was established with the Bravura Pass server but no response was detected. |
System Action | The active request will terminate. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | A number of factors can contribute to this condition. The Bravura Pass server may have failed or the pushpass service became unavailable. Network connectivity problems could also cause communication to the Bravura Pass server to terminate. If you are unable to determine the cause of the message, contact Bravura Security technical support for assistance. |
PSYNC963E
PSYNC963E – UNABLE TO ESTABLISH COMMUNICATION WITH PASSWORD MANAGER SERVER. RECONNECTION WILL BE ATTEMPTED IN FIVE MINUTES.
Explanation | PASSIVESTART=YES was specified in the Mainframe Connector start parameters and Mainframe Connector has not successfully test connected with the Bravura Pass server. |
System Action | Mainframe Connector will attempt a test connection with the Bravura Pass server every five minutes until a connection is established or until Mainframe Connector is stopped with an operator command. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | A number of factors can contribute to this condition. The Bravura Pass server may not be functional or the pushpass service is unavailable. Network connectivity problems could also cause communication to the Bravura Pass server to fail. If you are unable to determine the cause of the message, contact Bravura Security technical support for assistance. |
PSYNC964W
PSYNC964W – PASSWORD MANAGER SERVER CONNECTION TEST FAILED.
Explanation | A MODIFY mfc,CONNECTTEST command was issued and the test connection with the Bravura Pass server failed. |
System Action | None. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | A number of factors can contribute to this condition. The Bravura Pass server may not be functional or the pushpass service is unavailable. Network connectivity problems could also cause communication to the Bravura Pass server to fail. If you are unable to determine the cause of the message, contact Bravura Security technical support for assistance. |
PSYNC965E
PSYNC965E – RESET REQUEST TIMED OUT.
Explanation | A password reset request timed out in the subsystem funtion routine (PSNCF254) while waiting for a response from the Bravura Pass server. |
System Action | The password reset request continues. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | A number of factors can contribute to this condition. The Bravura Pass server may have failed or the pushpass service became unavailable. Network connectivity problems could also cause communication to the Bravura Pass server to terminate. If you are unable to determine the cause of the message, contact Bravura Security technical support for assistance. |
PSYNC966E
PSYNC966E – RESET REQUEST CONNECT FAILED.
Explanation | A password reset request experienced a network connection failure. |
System Action | The password reset request continues. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | A number of factors can contribute to this condition. The Bravura Pass server may have failed or the pushpass service became unavailable. Network connectivity problems could also cause communication to the Bravura Pass server to terminate. If you are unable to determine the cause of the message, contact Bravura Security technical support for assistance. |
PSYNC967E
PSYNC967E – LISTENER doaccept() select() errno nn
Explanation | The Mainframe Connector listener doaccept function routine experienced an error in a select function call. The errno value ’nn’ further describes the offending condition. |
System Action | The current inbound listener request terminates. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | An unexpected condition has occurred in select processing. If you are unable to determine the cause of the message, contact Bravura Security technical support for assistance. |
PSYNC968E
PSYNC968E – LISTENER doaccept() accept() errno nn
Explanation | The Mainframe Connector listener doaccept function routine experienced an error in an accept function call. The errno value ’nn’ further describes the offending condition. |
System Action | The current inbound listener request terminates. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | An unexpected condition has occurred in accept processing. If you are unable to determine the cause of the message, contact Bravura Security technical support for assistance. |
PSYNC969E
PSYNC969E – LISTENER socket() errno nn
Explanation | The Mainframe Connector listener failed to establish a socket connection on the socket specified on the LISTENPORT# Mainframe Connector start parameter. |
System Action | The listener function of Mainframe Connector terminates. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | An unexpected condition has occurred in socket processing. If you are unable to determine the cause of the message, contact Bravura Security technical support for assistance. |
PSYNC970E
PSYNC970E – LISTENER bind() errno nn
Explanation | The Mainframe Connector listener failed to establish a bind on the socket specified on the LISTENPORT# Mainframe Connector start parameter. |
System Action | The listener function of Mainframe Connector terminates. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | An unexpected condition has occurred in bind processing. If you are unable to determine the cause of the message, contact Bravura Security technical support for assistance. |
PSYNC971E
PSYNC971E – LISTENER listen() errno nn
Explanation | The Mainframe Connector listener failed to establish a listen status on the socket specified on the LISTENPORT# Mainframe Connector start parameter. |
System Action | The listener function of Mainframe Connector terminates. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | An unexpected condition has occurred in listen processing. If you are unable to determine the cause of the message, contact Bravura Security technical support for assistance. |
PSYNC972E
PSYNC972E – CLIENT socket() errno nn
Explanation | The Mainframe Connector outbound client failed to establish a socket connection on the socket specified on the TCPPORT# Mainframe Connector start parameter. |
System Action | The outbound request returns to the subsystem function caller. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | An unexpected condition has occurred in socket processing. If you are unable to determine the cause of the message, contact Bravura Security technical support for assistance. |
PSYNC973E
PSYNC973E – CLIENT connect() errno nn
Explanation | The Mainframe Connector outbound client failed to establish a connection on the socket specified on the TCPPORT# Mainframe Connector start parameter. |
System Action | The outbound request returns to the subsystem function caller. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | An unexpected condition has occurred in connect processing. If you are unable to determine the cause of the message, contact Bravura Security technical support for assistance. |
PSYNC974E
PSYNC974E – Mainframe Connector SUBSYSTEM DISABLED FROM PSNCF254.
Explanation | The Mainframe Connector address space has terminated without properly disabling its subsystem. |
System Action | The active subsystem function routine has disabled the Mainframe Connector subsystem. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | An unexpected condition has occurred with the Mainframe Connector started task. If you are unable to determine the cause of the message, contact Bravura Security technical support for assistance. |
PSYNC975E
PSYNC975E – Mainframe Connector SUBSYSTEM DISABLED FROM PSNCF254.
Explanation | The Mainframe Connector address space has terminated without properly disabling its subsystem. |
System Action | The active subsystem function routine has disabled the Mainframe Connector subsystem. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | An unexpected condition has occurred with the Mainframe Connector started task. If you are unable to determine the cause of the message, contact Bravura Security technical support for assistance. |
PSYNC976E
PSYNC976E – Mainframe Connector SUBSYSTEM DISABLED FROM PSNCF254.
Explanation | The Mainframe Connector address space has terminated without properly disabling its subsystem. |
System Action | The active subsystem function routine has disabled the Mainframe Connector subsystem. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | An unexpected condition has occurred with the Mainframe Connector started task. If you are unable to determine the cause of the message, contact Bravura Security technical support for assistance. |
PSYNC978E
PSYNC978E – NAME/TOKEN CREATE FAILED RC(XX). Mainframe Connector TERMINATING.
Explanation | The Mainframe Connector main driver task failed to successfully create the NAME/TOKEN entry associated with this subsystem activation. |
System Action | The activation of this Mainframe Connector subsystem is terminated. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | An unexpected condition has occurred with the Mainframe Connector started task. If you are unable to determine the cause of the return code indicated by ’xx’, contact Bravura Security technical support for assistance. |
PSYNC981I
PSYNC981I – USERID xxxxxxxx NOT LOCATED IN PSNCUIDT
Explanation | Multiple Mainframe Connector subsystems are operational. A password reset request is being processed through either a Mainframe Connector security product "new password" exit or a PSNCSSC API call and no UIDENTRY exists in the PSNCUIDT table to match the userid indicated by ’xxxxxxxx’. |
System Action | The current request is abandoned by Mainframe Connector . |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | This may be an acceptable condition. If the specified userid is not to be processed by any of the active subsystems, then the message can be ignored. If the userid should be processed by one of the active Mainframe Connector subsystems, a UIDENTRY for this userid should be supplied in the PSNCUIDT source deck. If a UIDENTRY does exist for this userid in the PSNCUIDT table, contact Bravura Security technical support for assistance. |
PSYNC982I
PSYNC982I – PSNCUIDT TABLE FORMAT ERROR
Explanation | Multiple Mainframe Connector subsystems are operational. A password reset request is being processed through either a Mainframe Connector security product "new password" exit or a PSNCSSC API call and a PSNCUIDT table has been located, but the table has a format that is not recognized as valid. |
System Action | The current request is abandoned by Mainframe Connector . |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | This would represent a highly unusual condition. If the PSNCUIDT table was created using the supplied UIDSSN macro, contact Bravura Security technical support for assistance. |
PSYNC983I
PSYNC983I – SPECIFIED SUBSYSTEM xxxx NOT ACTIVE FOR USERID uuuuuuuu
Explanation | Multiple Mainframe Connector subsystems are operational. A password reset request is being processed through either a Mainframe Connector security product "new password" exit or a PSNCSSC API call, a PSNCUIDT table has been located, a UIDENTRY table entry for userid ’uuuuuuuu’ has been located, but the corresponding Mainframe Connector subsystem is not currently active. |
System Action | The current request is abandoned by Mainframe Connector . |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | This is most likely a valid condition and the specified subsystem is simply not currently operational. If the subsystem specified by ’xxxx’ is operational, contact Bravura Security technical support for assistance. |
PSYNC984I
PSYNC984I – NO PSNCUIDT TABLE LOCATED AND MULTIPLE Mainframe Connector SUBSYSTEMS WERE DETECTED.
Explanation | Multiple Mainframe Connector subsystems are operational. A password reset request is being processed through either a Mainframe Connector security product "new password" exit or a PSNCSSC API call and a PSNCUIDT table was not located. |
System Action | The current request is abandoned by Mainframe Connector . |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | If multiple Mainframe Connector subsystems are operational and the Mainframe Connector security product new password exit is active or the PSNCSSC API call is being used, a PSNCUIDT table is required to direct the request to the proper Mainframe Connector subsystem. |
PSYNC985I
PSYNC985I – DEFAULT SUBSYSTEM xxxx NOT ACTIVE FOR USERID uuuuuuuu
Explanation | A password reset request is being processed through either a Mainframe Connector security product "new password" exit or a PSNCSSC API call, a PSNCUIDT table has been located, a UIDENTRY table entry for userid ’uuuuuuuu’ has been located, but the specified default Mainframe Connector subsystem is not currently active. |
System Action | The current request is abandoned by Mainframe Connector . |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | This is most likely a valid condition and the specified subsystem is simply not currently operational. If the subsystem specified by ’xxxx’ is operational, contact Bravura Security technical support for assistance. |
PSYNC990E
PSYNC990E – Mainframe Connector SUBSYSTEM HAS BEEN DISABLED BY RESOURCE MANAGER.
Explanation | The Mainframe Connector main task has terminated and recovery termination discovered that the Mainframe Connector subsystem had not been properly disabled. |
System Action | The Mainframe Connector subsystem is disabled by the Mainframe Connector resource manager. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | This message would indicate a very unusual condition for Mainframe Connector . In general, it could only happen if a catastrophic abend occurred in the Mainframe Connector main task and the corresponding ESTAE was not invoked. Notify Bravura Security technical support immediately. |
PSYNC999I
PSYNC999I – Mainframe Connector ICHPWX01 UNABLE TO LOCATE RACF RCVT.
Explanation | The ICHPWX01 RACF exit installed to support Mainframe Connector was not able to locate the RACF anchor control block, the RCVT. |
System Action | Mainframe Connector new password processing will not be active. |
Operator Response | Report this condition to the system programmer. |
System Programmer Response | If Mainframe Connector has been installed on a system running RACF contact Bravura Security technical support. The internal control block structures for RACF have been compromised. |